Vac-U-Chamber Only, Large & Related Items |
|
Vac-U-Chamber
Uses Negative Pressure to Avoid Pump Contamination
Features
- Allows direct filling of air sample bags
• Uses negative pressure provided by most personal air sample pumps
• Designed to contain SKC sample bags
- Protects from contamination
• Sample does not pass through the pump
• Inert surfaces eliminate sample contamination
- Rugged heavy-duty construction
• Will not collapse under vacuum
- Two sizes available
• Large for sample volumes up to 8 liters
• Small for sample volumes up to 1 liter
Vac-U-Chamber
Spec. Sheet (PDF)
The SKC Vac-U-Chamber
For Convenient, Reliable Bag Sampling
The SKC Vac-U-Chamber is a rigid air sample box that allows sample bags
to be filled directly by using negative pressure provided by most personal air
sample pumps. Since the air sample does not pass through the pump, both
pump and sample contamination are eliminated. All surfaces in contact with
the sample are constructed of inert materials. The Vac-U-Chamber’s rigid
walls will not collapse under vacuum conditions.
Multiple Applications
- Stack sampling
- Ventilation studies
- Hazmat testing
- Soil gas sampling
- Groundwater testing
- Ambient or indoor air sampling
- EPA Method 0040
Using the Vac-U-Chamber
The Vac-U-Chamber is equipped with three 1/4-inch OD fitting ports for inflating sample bags:
- Sample inlet port for connecting to the sample line or gas source
- Purge port for purging the air prior to sampling or when preparing the bag for a standard
- Vacuum port for inflating a bag
An air sample bag is connected to the inside sample inlet port and the chamber is closed, providing an airtight seal. An air sample pump is connected to the outside vacuum outlet port. When activated, the pump evacuates air from inside the chamber. The sample bag inflates as a result of the interior pressure drop. This pneumatic technique allows the air sample to enter the bag directly without passing through the pump, protecting the pump from sample contaminants and the sample from pump contaminants.
Ordering Information
Large Vac-U-Chamber
| Description |
Cat. No. |
Complete Vac-U-Chamber Kit includes PCXR4 sample pump, single
PowerFlex charger with cable, large Vac-U Chamber, and ten 236-004 sample
bags
100-240 V
| 224-4115 |
| Large Vac-U-Chamber only with stainless steel fittings (supplied
without pump), suitable for use with 236-004 bags |
231-939 |
| 8-liter FlexFilm Bag with single polypropylene fitting, 12 x 18.25
inches (30.5 x 46.4 cm), for use with large Vac-U-Chamber (Cat. No. 231-939),
pk/10 |
236-004 |
| Quick Disconnect with tubing for replacement in Cat. No. 231-939 |
P231941 |
| PTFE Tubing, 5/16-inch OD (1/4-inch ID), 10 feet |
231-937 |
| PTFE Tubing, 5/16-inch OD (1/4-inch ID), 50 feet |
231-924 |
Small Vac-U-Chamber
| Description |
Cat. No. |
Complete Vac-U-Chamber Kit includes PCXR4 sample pump, single PowerFlex charger with cable, small Vac-U-Chamber, and ten 232-01 sample bags
100-240 V |
224-4124 |
| Small Vac-U-Chamber only with polypropylene
fittings (supplied without pump), suitable for use with 236-001 or 232-01 bags |
231-940 |
| 1-liter Tedlar Bag with single polypropylene fitting, 7 x 7 inches
(17.7 x 17.7 cm), for use with small Vac-U-Chamber (Cat. No. 231-940) and
included in 224-4124 kit, pk/10 |
232-01 |
| 1-liter FlexFilm Bag with single polypropylene fitting, 8.25
x 8.25 inches (21 x 21 cm), for use with small Vac-U-Chamber (Cat. No.
231-940), pk/10 |
236-001 |
The Vac-U-Chamber is available in other sizes and fittings as a custom order. Contact your SKC
representative for more information.
Vac-U-Chamber
Spec. Sheet (PDF)
This page was last modified August 3, 2010
|

|
|
|
 |